The electric meter talks on an encrypted 900 MHz mesh, so I can't read it off the air. I put an Emporia Vue 3 in the panel and reflashed it, and tapped the furnace's control bus for the HVAC side.
Power
Emporia Vue 3 (ESP32) on ESPHome, CTs on both 200 A mains
Stock firmware
Backed up before flashing
HVAC
M5 AtomS3 Lite on an RS485 base, on the Rheem communicating bus
Furnace
84,000 BTU/h high fire, 59,000 low, 97% AFUE - reported by the furnace
Energy
No Emporia cloud. The Vue reports power and voltage on both phases straight to Home Assistant, and the Energy dashboard is built from that.
Furnace
esphome-econet speaks Rheem's protocol, so I get what the furnace knows - return air temperature, blower CFM, static pressure, flame current, heat output and cycle counts.
I took fan control out of HA. The thermostat rejected fan changes from the bus and then jumped the setpoints to 62 and 85, so the fan stays on the wall thermostat.